Roof condition survey Brindle Court, Marlbury |
| Client | Brindlewood Property Group Ltd |
| Site address | Brindle Court, 8 to 22 Foundry Lane, Marlbury |
| Postcode | MB3 6IM |
| Survey date | 19 Mar 2026 |
| Surveyor | Marcus Feld | GVC, BSc (Hons) |
| Pilot | Marcus Feld |
| Roof type | Pitched concrete tile; flat felt |
| Delivery | https://portal.example.test/deliveries/P-2026-0088 |
| Red: 1 | Amber: 1 | Green: 1 |
Sample report
| Roof condition survey | RK-2026-0421 |
Document control
Status code: A1
| Revision | Date | Status | Description | Author | Checked | Approved |
|---|---|---|---|---|---|---|
| P01 | 22 Mar 2026 | Draft | Draft for internal check | MF | EW | |
| A | 24 Mar 2026 | Issued | First issue to client | MF | EW | EW |
Distribution
| Name | Organisation | Copies |
|---|---|---|
| Priya Lennox | Brindlewood Property Group Ltd | 1 |
| Roof condition survey | RK-2026-0421 |
RAG guidance
| Roof condition survey | RK-2026-0421 |
Red — Serious defect requiring urgent attention.
- Critical safety, structural or compliance risk
- Immediate repair or specialist investigation
- Examples: active leaks, unsafe electrics, structural instability
Amber — Defect requiring attention; plan remedials.
- Not immediately dangerous but may worsen
- Schedule and monitor
- Examples: moderate corrosion, loose fixings, minor water staining
Green — Minor observation; no immediate action.
- Low risk, no current impact
- Routine maintenance cycles
- Examples: minor staining, hairline mortar shrinkage, cosmetic wear
Highlight — Non-RAG highlight; counted separately.
- Advisory notes, best-practice recommendations, enhancements
- Not a defect
- Examples: energy upgrades, accessibility improvements, modernisation opportunities
| Roof condition survey | RK-2026-0421 |
Tag guidance
Tags add context to each fault and allow the fault index to be filtered. The tags used in this report are:
| Tag | Use where |
|---|---|
| Water ingress | Use where there is evidence of water entering the building or build-up: staining, damp patches, drips, saturated insulation or active leaks. |
| Structural issue | Use where the defect affects the load-bearing or supporting structure: deflection, movement, cracked or failed members, undersized or decayed supports. |
| Vegetation | Use where moss, lichen, weeds, grass or self-seeded plants are growing on the roof, facade, gutters or outlets. |
| Blocked gutters | Use where gutters, hoppers or outlets are blocked by debris, silt, leaves or vegetation so that rainwater cannot discharge. |
| Electrical hazard | Use where exposed, damaged or poorly supported cables, fittings, lightning protection or solar equipment create a shock or fire risk. |
| Access risk | Use where safe access for maintenance or inspection is restricted, unprotected or hazardous: fragile coverings, missing edge protection, poor fixings for ladders. |
| Fixings issue | Use where fixings, clips, screws, bolts or straps are loose, missing, corroded, over-driven or incorrectly specified. |
| Rooflight issue | Use where rooflights, lanterns or glazed roof panels are damaged, discoloured, leaking, loose or fragile. |
| Wind damage | Use where the defect is attributable to wind uplift or wind-driven impact: lifted sheets, displaced tiles, torn membranes, peeled flashings. |
| Falling debris | Use where loose material could fall and injure people or damage property below: loose tiles, render, masonry, cappings or glazing. |
| H&S risk | Use where the defect presents a health and safety risk to occupants, the public or operatives, beyond the specific hazard tags. |
| Impact damage | Use where damage has been caused by impact: foot traffic, dropped tools, plant, vehicles, hail or falling objects. |
| Mortar issues | Use where bedding, pointing or jointing mortar is cracked, eroded, missing or loose to ridges, hips, verges, chimneys or masonry. |
| Flashing issues | Use where lead, metal or proprietary flashings and soakers are lifted, split, corroded, missing or poorly dressed. |
| Cut end corrosion | Use where the cut or exposed edges of coated metal sheets, cladding or trims show edge corrosion or coating peel-back. |
| Corrosion | Use where metal components show rust, oxidation, pitting or coating breakdown beyond the cut edge. |
| Reduced daylight | Use where rooflights or glazing are dirty, discoloured, overpainted or covered so that natural daylight is reduced. |
| Restricted gutter | Use where the gutter cross-section or outlet is reduced by a liner, sag, debris build-up or incorrect fall rather than fully blocked. |
| Delamination | Use where layers of a sheet, panel, membrane, render or coating are separating, blistering or peeling apart. |
| Roof condition survey | RK-2026-0421 |
Survey summary
Report Kit 360 was commissioned by Brindlewood Property Group Ltd to undertake an external roof condition survey at Brindle Court, 8 to 22 Foundry Lane, Marlbury.
Our brief was to provide secondary commentary on the roof and gutter conditions, identifying visible defects, their likely risk and a recommended course of action for each.
This report should be read alongside the complete image pack, available within our secure, password-protected client portal: https://portal.example.test/deliveries/P-2026-0088
Password: Supplied separately
We have provided within our report photographic evidence of each observation. The survey was a non-invasive visual survey carried out from the positions described; no materials were disturbed, lifted or tested. The findings are summarised as 1 red, 1 amber and 1 green observations.
| Roof condition survey | RK-2026-0421 |
Site overview
Figure 1 — Site overview from the south-west
Figure 2 — Sectioned overview: red = block A, blue = block B, green = flat roof
Roof section colour guidance
Sections of the roof are identified on the sectioned overview by the colours below (colour-coded sections).
| Colour | Reference |
|---|---|
| Red | #ff0000 |
| Blue | #0000ff |
| Green | #00ff00 |
| Pink | #ff00ff |
| Orange | #ff9900 |
| Black | #000000 |
| Sky blue | #00ccff |
| Purple | #9900cc |
| Yellow | #cccc00 |
| Roof condition survey | RK-2026-0421 |
1 Section overview
1.1 Section Section
Figure 1.1 — Sectioned overview: red = block A, blue = block B, green = flat roof
Section summary
Section red (block A): concrete interlocking tiles on a 35° pitch with a dry-fix ridge. Three broken tiles at the eaves above the entrance and two slipped tiles mid-slope. Gutters silted with moss. Lead flashings to the stair-core abutment are split on the east side. Condition fair; red items to be dealt with promptly.
| Roof condition survey | RK-2026-0421 |
2 Photograph
Photograph 1 — Eaves above the entrance, block A (Red)
| # | Rating | Detail | Fault type | Tags |
|---|---|---|---|---|
| #1 | Red | Broken tiles | Falling debris Water ingress | |
Defect: three broken interlocking tiles at the eaves directly above the entrance. Risk: fragments falling onto the entrance path; water tracking into the eaves. Recommendation: replace the tiles and check the eaves felt within one month; cordon the path below until done. | ||||
| #2 | Amber | Slipped tiles | Fixings issue | |
Two slipped tiles mid-slope; refix with clips at the same visit. | ||||
| #3 | Green | Moss growth | Vegetation | |
Light moss on the north slope; clean when the gutters are cleared. | ||||
| Roof condition survey | RK-2026-0421 |
Fault index
Every fault in this report, in report order, with its photograph, RAG rating and fault type.
| Roof condition survey | RK-2026-0421 |
Appendix A — Drone flight record
The survey imagery was captured by unmanned aircraft. The flight record below is kept in line with the UK CAA remote-pilot and operator logbook requirements.
Operator and pilot
| Operator ID | GBR-OP-EXAMPLE1234 | Operational authorisation / GVC reference | OA-EX-2041 (GVC) |
|---|---|---|---|
| Remote pilot | Marcus Feld | Flyer ID | FLY-EX-204871 |
| Insurance policy / expiry | Policy EX-UAS-77812, expires 2026-11-30 | Site risk assessment reference | RA-BC-2026-02 |
| Airspace / NOTAM check | Checked; no NOTAMs; outside controlled airspace |
Table A.1 — Flight log
| Date | Take-off / landing location | Duration | Day / night | Aircraft make / model / serial | Weather | Occurrences |
|---|---|---|---|---|---|---|
| 2026-03-19 | Car park, north end | 14 min | Day | DJI Mavic 3 Enterprise | Dry, 8 °C, wind 3 m/s | None |
| Roof condition survey | RK-2026-0421 |
Declaration
I confirm that the photographs in this report were taken on the survey date at the site stated and that the observations represent my professional opinion of the condition visible at that time.
Prepared by Marcus Feld Report Kit 360 Date: 24 Mar 2026 | Checked by Eleanor Whitcombe Report Kit 360 Date: 24 Mar 2026 |